A Procurement Manager's FAQ on FARO Portable CMMs, Insulation Testers, and Weighing Systems
-
Where these questions come from
-
What does a FARO portable CMM or laser tracker actually cost, all-in?
-
Why do quotes for the same FARO portable CMM come back 30% apart?
-
Is the Fluke 1587 FC insulation multimeter worth the premium over cheaper meters?
-
When does a 1555 insulation tester make sense instead of a 1587 FC?
-
What programming language do Rice Lake weighing systems use?
-
How do I spot a vendor that's hiding fees before I sign?
-
Which line item do procurement teams most often underbudget?
Where these questions come from
I'm a procurement manager at a 400-person industrial manufacturing company. Over the past six years I've managed roughly $3.8M in test and measurement spend — laser trackers, portable CMM arms, insulation testers, weighing systems, and everything in between that you can't just order from a catalog. This post is a cleaned-up version of the questions I keep getting from colleagues and from vendors, plus the ones I wish someone had asked me back in 2021 before I signed our first metrology contract.
I'm writing from a cost-controller perspective. Where something is outside my lane, I'll say so.
What does a FARO portable CMM or laser tracker actually cost, all-in?
Public list pricing is hard to find because FARO sells through reps, not e-commerce. From the seven quotes we pulled between Q3 2024 and Q1 2025, a portable CMM arm or an entry laser tracker landed anywhere from the low five figures to the mid six figures — the spread is enormous because of configuration: working volume, probe options, software licenses, and whether a calibration contract is bundled.
The number procurement tends to budget for is the unit price. The number that matters is TCO. What sits outside the quote typically includes:
- Annual calibration and recertification
- Software subscription or maintenance renewals
- Operator training (often quoted per seat, per session)
- Transit cases rated for precision instruments — $2,000-4,000, and not always on the sheet (unfortunately, we found this out after the fact)
- Repair deposits or be-spoke support tiers
I'm not a metrology engineer, so I can't tell you whether a specific volumetric accuracy spec matters for your part tolerance. What I can tell you from a procurement seat is that the accuracy figure is the least negotiated line on the quote — nobody ever gets a discount for accepting looser tolerance, but everyone pays for it later in calibration cycles.
Why do quotes for the same FARO portable CMM come back 30% apart?
Because they're not the same system. In our 2023 audit, we compared four quotes that all said "portable CMM" in the subject line. Three of them were different arm lengths with different software bundles. The fourth was a laser tracker quote mislabeled by the rep. Once we normalized the specs, the real spread was under 8%.
Our procurement policy now requires quotes from at least three vendors with a normalized spec sheet attached, largely because of that comparison. The lesson wasn't that one vendor was cheating — it was that "portable CMM" is a category, not a configuration.
Is the Fluke 1587 FC insulation multimeter worth the premium over cheaper meters?
Depends entirely on what you're testing. The 1587 FC is a combined multimeter and low-voltage insulation tester — insulation testing up to 1,000V, plus standard DMM functions and a temperature probe. The FC designation means it pairs with Fluke's app for logging and trending, which sounds like a gimmick until you're the person who has to prove quarterly insulation readings to an auditor.
We buy them for field technicians who need both functions on one belt. For a bench tech who only does continuity checks, it's overkill and the cheaper meter wins. I've never regretted buying the higher-spec instrument for a technician who uses it daily; I have regretted buying it for a drawer.
When does a 1555 insulation tester make sense instead of a 1587 FC?
When your test voltage requirement goes above 1kV. The 1555 is a dedicated 5kV insulation tester — it's built for motors, cables, transformers, and switchgear where you need to stress insulation at higher voltages. The 1587 FC tops out at 1kV.
From a budget standpoint, these are not interchangeable line items. The 1555 is a specialized instrument with a specialized price, and if your maintenance team is testing medium-voltage equipment, buying the 1587 FC to save money just means renting a 1555 twice a year plus paying expedite fees. We ran that math once. It didn't favor renting.
One caveat: I can't speak to your specific test standard requirements. Verify against whatever standard your facility is held to before you standardize on a model.
What programming language do Rice Lake weighing systems use?
This comes up more than you'd expect, usually from an IT or automation person who's been handed a weighing project. The honest answer is: it depends on the indicator, because there isn't one language.
Rice Lake's 920i indicator is programmable in a form of ladder logic — it's not a general-purpose language, it's a control-logic environment. Their iQUBE2 and similar junction boxes are configured through PC-based software rather than coded by hand. And most of the integration work on their systems happens through serial or Ethernet protocols (Modbus, EtherNet/IP, and similar) rather than through "writing code" in the traditional sense.
If you're scoping a project, ask the integrator to specify which indicator model and which interface protocol — "what language does Rice Lake use" is a question that only has a useful answer once you know the hardware. Confirm current capabilities directly with Rice Lake or your integrator; I'd rather point you there than guess at a spec that changed after the last time I checked (that was early 2024).
How do I spot a vendor that's hiding fees before I sign?
Ask "what's NOT included" before you ask "what's the price." That one habit has saved us more money than any negotiation tactic I've used.
Specific red flags I've learned to check:
- Calibration terms buried in an appendix — is the first year included or not?
- Freight and insurance — precision instruments ship special; who pays, and is it insured at replacement value?
- Training — is it on-site, per-seat, or self-serve video?
- Repair turnaround SLAs — is a loaner included during service, or does downtime come out of your production budget?
I've learned to be skeptical of the lowest quote when the lowest quote is also the shortest. The vendor who lists every fee up front — even if the total looks higher — usually costs less by the time the invoice clears. I've seen a "free setup" offer turn into $450 of hidden line items (ugh). It's a small number in isolation; across a portfolio, it's not.
Which line item do procurement teams most often underbudget?
Calibration and downtime. Not hardware.
We didn't have a formal calibration-log requirement in our POs for the first two years. It cost us when we couldn't produce a record during an audit and had to re-certify three instruments on a rush schedule. The third time something like that happened, I built a tracking sheet and made calibration due dates a mandatory field on every purchase order. Should have done that after the first incident, honestly.
Looking back, I should have paid for the extended service contract on our first laser tracker. At the time, the standard warranty window seemed safe. It wasn't — the first out-of-warranty repair was a four-figure bill, and it arrived three weeks after the coverage lapsed. Given what I knew then, the choice was reasonable. Given what I know now, I'd budget service at 8-12% of acquisition cost annually and treat it as non-negotiable.
These figures are from our own records and from quotes pulled between Q3 2024 and Q1 2025. Pricing and service structures change fast in this industry — verify current rates before you put anything in a budget. And none of this replaces talking to someone who actually understands the measurement problem you're trying to solve; that person isn't usually in procurement.
Leave a Reply